The FastGene® Electronic Pipette is a Japanese masterpiece. The precision achieved by our pipettes is astonishing. With the FG-EP10 the accuracy at 1 µl is 4% meaning that if you pipette 1 µl you will get a variance of ±0.04 µl, giving you the perfect volume control and this every single time you activate the pipette.
The FastGene® Electronic Pipette comes with an easy to read display containing all the information, such as pipetting mode, volume remained in the tip, blowout function, intensity of the aspiration and dispensing and the battery status. The setting up of the FastGene® Electronic Pipette is very easy and straight forward, so that the user will be an expert in no time.
Program the FastGene® Electronic Pipette with your favorite settings, such as pipetting mode, aspiration/dispensing intensity, volume, etc.. The FastGene® Electronic Pipette comes with a program storage for up to 9 programs, so that each user can have its own program.
The FastGene® Electronic Pipette is calibratable by the user. Even more, the user can calibrate to liquid volumes or to a weight unit, useful for liquids with solids or powders diluted in them, making difficult density calculation unnecessary.
The FastGene® Electronic Pipette comes with a rechargeable Lithium-ion battery with 920 mAh. This battery is enough for 1800 pipetting cycles, giving you the autonomy of working wherever you need it.
The FastGene® Electronic Pipette comes with three pipetting modes:
Model | FG-EP10 | FG-EP200 | FG-EP1200 | ||||
Volume Range | 0.5 to 10.0 µl | 10 to 200 µl | 100 to 1200 µl | ||||
Increment | 0.1 µl | 1 µl | 1 µl | ||||
Performance | Volume | 1.0 µl | 10.0 µl | 10 µl | 200 µl | 100 µl | 1200 µl |
Accuracy | 4.0 % | 1.0 % | 2.5 % | 0.6 % | 2.5 % | 0.5 % | |
Repeatability (CV) | 2.5 % | 0.4 % | 1.0 % | 0.15 % | 0.6 % | 0.15 % | |
Program storage | 9 Programs | ||||||
Aspiration level | 5 speeds | ||||||
Length | 28 cm | ||||||
Weight | 150 g | 170 g |
Pipette | Tip maker | Model number | Compatibility | Remarks |
FG-EP10 | Gilson | D10 | Compatible | |
DL10 | Incompatible | Not possible to affix tip | ||
Eppendorf | epT.I.P.S. Standard | Compatible | ||
Rainin | RC-10 | Compatible | ||
Biohit | 790014 | Compatible | ||
Thermo | Flex10 | Compatible | ||
BRAND | 702504 | Compatible | ||
Nichiryo | BMT-SS | Compatible | ||
QSP | 101 | Compatible | ||
114 | Incompatible | Not possible to affix tip | ||
Watson | 207C | Compatible | ||
Nippon Genetics | FG-FT10S | Compatible | ||
FG-FT10L | Compatible | |||
Labcon | 1038 | Compatible | ||
FG-EP200 | Gilson | D200 | Compatible | |
Eppendorf | epT.I.P.S. Standard | Compatible | ||
Rainin | RC-250 | Compatible | ||
Biohit | 790204 | Compatible | ||
Thermo | Flex200 | Compatible | ||
BRAND | 702516 | Compatible | ||
Nichiryo | BMT-SE | Compatible | It is necessary to adjust the height of the tip ejector | |
QSP | 110-NEW | Compatible | ||
110-N | Compatible | |||
110-B | Compatible | |||
Watson | 705Y | Compatible | ||
Nippon Genetics | FG-FT200 | Compatible | ||
Labcon | 1093 | Compatible | ||
FG-EP1200 | Gilson | D1000 | Caution | At aspiration of 1200uL, the tip holder becomes wetted Use is possible at aspiration of 1000uL |
Eppendorf | epT.I.P.S. Standard | Compatible | ||
Rainin | RC-1000 | Compatible | ||
Biohit | 791005 | Compatible | ||
Thermo | Flex1200 | Compatible | ||
BRAND | 702521 | Compatible | ||
Nichiryo | BMT-L | Compatible | ||
QSP | 111 | Compatible | ||
Watson | 706B | Compatible | ||
Nippon Genetics | FG-FT1000 | Caution | At aspiration of 1200uL, the tip holder becomes wetted Use is possible at aspiration of 1000uL | |
Labcon | 1045 | Compatible | ||
Greiner Bio-One | 750251 | Compatible |
Cat.Nr.: | Product | Volumes |
FG-EP10 | FastGene® Electronic Pipette 10 µl | 0.5 µl to 10 µl |
FG-EP200 | FastGene® Electronic Pipette 200 µl | 10 µl to 200 µl |
FG-EP1200 | FastGene® Electronic Pipette 1200 µl | 100 µl to 1200µl |